iOLM technology eases FTTx/PON network testing

23 January 2013 Test & Measurement

Of the current test methods for testing FTTx (Fibre to the ‘x’, with x being a placeholder for various end-points) and PON (passive optical network) installations, OLTS, using an optical loss test set (optical power meter and light source) to characterise a link is easy; however it has one major limitation: it cannot locate the problems on the link. Furthermore, an OLTS requires two units and two technicians, thus increasing OPEX.

Figure 1. End-to-end test with a pair of OLTS units. This method may be fast, but will not locate the problem on the link.
Figure 1. End-to-end test with a pair of OLTS units. This method may be fast, but will not locate the problem on the link.

The most popular test method during construction and in certifying FTTX/PON installations is an OTDR (optical time domain reflectometer). A well trained and skilled optical technician can identify and locate problems on a link, using multiple acquisitions with different OTDR test settings and after various manual OTDR trace comparisons.

Figure 2. Incomplete OTDR test results on a 1x32 PON due to improper testing parameters set by a technician who is lacking OTDR testing experience.
Figure 2. Incomplete OTDR test results on a 1x32 PON due to improper testing parameters set by a technician who is lacking OTDR testing experience.

The shift from copper to fibre and the explosion of fibre deployments has created a shortage of skilled and experienced technicians. Combine this with budget constraints, lack of credible training facilities, practical experience and the result is an increased risk of improper testing, misdiagnoses, unusable OTDR results and repeat repairs/truck rolls.

Figure 3. Portable test setup with launch and receive fibres for a PON-line certification with a 1x32 splitter.
Figure 3. Portable test setup with launch and receive fibres for a PON-line certification with a 1x32 splitter.

The complexity of a PON/FTTx network requires skilled optical technicians to set different acquisition parameters on the OTDR to get the required information. Single OTDR measurement and auto test settings on today’s OTDRs are incapable of fully characterising this type of network.

To overcome this limitation, skilled technicians perform multiple additional acquisitions on the OTDR with other parameters to fully characterise the link.

Figure 4. Example of test results. All the information, including diagnostics, is provided in a single view.
Figure 4. Example of test results. All the information, including diagnostics, is provided in a single view.

Portable applications

EXFO’s new test solution is an ‘intelligent’ OTDR. Essentially it is a software application that runs on the test unit that is able to set and take multiple and variable acquisitions, then analyse the information to generate a detailed linear diagram about every element on the link, in a single-button operation, providing maximum simplicity for expert-level link characterisation.

This new test method makes every technician a fibre-optics expert, whether they are testing in the field or from the central office. Plus, it does not require the parameter settings used in traditional OTDR testing, which means no distance, pulse width or averaging time setting with detection threshold setting required.

iOLM (intelligent Optical Link Mapper) technology stems from the need to create optimal testing technology for PON networks, as this is the most challenging network to test because of its short link lengths and many closely spaced elements, such as splices, connectors and splitters.

As shown in Table 1, the maximum IL difference between iOLM and the reference method (PM/LS) is 0,64 dB, which compares favourably to the OLTS method. Based on the PM/LS and the OLTS results, an experienced technician could have suspected a macrobend on the line because the difference in loss is more than 1 dB between 1310 and 1550 nm.

Table 1. IL test results from the different methods.
Table 1. IL test results from the different methods.

However, he would have no clue as to the location of the macrobend. He could therefore use an OTDR and a different combination of pulse widths to find the macrobend himself. With iOLM any technician will be able to clearly see that there is a macrobend immediately after the splitter (see Figure 5 showing a test conducted from ONT to OLT).

Figure 5. Image showing the position of a macrobend once analysed by a portable OTDR with multi-pulse acquisition and analysis capabilities.
Figure 5. Image showing the position of a macrobend once analysed by a portable OTDR with multi-pulse acquisition and analysis capabilities.

The test method is a one-end, single-unit testing method with the ability to provide clear diagnostics and discovered elements in a single view.

Comparing ORL measurements (Table 2), the maximum difference between the ORL meter and iOLM is 0,84 dB, which is small enough to locate any ORL problem.

Table 2. Table showing the different ORL test results.
Table 2. Table showing the different ORL test results.

So what is causing an ORL issue on the line?

This is caused by connector reflectance, but according to the ORL results, we are below the 32 dB threshold. Now, if we look at the results in Figure 6, we can see that there is one highly reflective connector that needs to be fixed (exceeds the -55 dB threshold).

Figure 5. Image showing the position of a macrobend once analysed by a portable OTDR with multi-pulse acquisition and analysis capabilities.
Figure 5. Image showing the position of a macrobend once analysed by a portable OTDR with multi-pulse acquisition and analysis capabilities.

This is what we are looking for when testing with an ORL meter (or OLTS) in both directions. We want to know the direction of the high ORL because that is where the high reflective connector is. Obviously, we would have missed it with the ORL meter or the OLTS, providing a clear advantage for the iOLM.

For more information contact Chris Nel, Lambda Test Equipment, +27 (0)12 349 1341, [email protected], www.lambdatest.co.za



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

High-speed AWG generates up to 20 sine waves
Vepac Electronics Test & Measurement
Spectrum Instrumentation has released a new firmware option for its range of versatile 16-bit Arbitrary Waveform Generators, with sampling rates up to 1,25 GS/s and bandwidths up to 400 MHz.

Read more...
Digitisers upgraded with pulse generator option
Vepac Electronics Test & Measurement
Spectrum Instrumentation has added the Digital Pulse Generator option to its ultrafast digitisers (with up to 10 GS/s speed) and arbitrary waveform generators.

Read more...
Network Master Pro to provide support of OpenZR+
Tamashi Technology Investments Test & Measurement
Anritsu Corporation has introduced the 400G (QSFP-DD) multi-rate module MU104014B that supports the new interface standard.

Read more...
Upgrade brings extra layer of detection to Fluke’s acoustic imagers
Comtest Test & Measurement
The firmware 5.0 update helps to boost efficiency and allows maintenance technicians to scan large areas quickly, and visually pinpoint technical issues before they become critical.

Read more...
Companies collaborate on EnviroMeter
Avnet Silica Test & Measurement
STMicroelectronics and Mobile Physics have joined forces to create EnviroMeter for accurate air-quality monitoring on smartphones. Time-of-flight optical sensing enables an accurate personal air quality monitor and smoke detector.

Read more...
PCB test points
Vepac Electronics Test & Measurement
Maintaining these access points in the final production versions will prove invaluable during the life of the equipment for service, adjustment, and debug, or repair activities.

Read more...
RFID reader
Test & Measurement
The EXA81 from Brady turns any smartphone or tablet into a personal radar that can pick up radio signals from all RFID-labelled items.

Read more...
Proximity sensor with VCSEL
Avnet Abacus Test & Measurement
Vishay’s newest small package proximity sensor, the VCNL36828P, combines low idle current with an I2C interface and smart dual slave addressing.

Read more...
CNH data output devices for AI applications
Altron Arrow Test & Measurement
STMicroelectronics’ CH family of time-of-flight sensor devices feature compact and normalised histogram (CNH) data output for artificial intelligence applications requiring raw data from a high-performance multizone ToF sensor.

Read more...
Webinar: The key to smart occupancy
Test & Measurement
This one-hour session will allow the attendee to discover the company’s latest infrared sensor with high-sensitivity presence and motion detection capabilities.

Read more...