At Schroff, ‘electronic packaging’ means more than just 19” plug-in units and subracks. It means the integration of electro-mechanical and electronic components, such as backplanes, power supplies, switches and cabling into an enclosure system. Technical solutions for EMC, cooling and monitoring belong to the service package in the same way as assembly and fast track deliveries.
CompactPCI systems for horizontal board assembly
Standard CompactPCI systems can, for example, form the basis of an integrated system, whereby all necessary additional items such as disk drives, peripherals and I/O can be built into the standard system prior to delivery. The system slot is located at the bottom, therefore CPUs of double width (8 HP) can be used. Additionally there is an assembly space for horizontal, 80 mm deep, rear I/O boards with IEEE guide rails inclusive ESD clips. At the left side of the system is a pluggable hot-swappable cooling unit with four integrated, quiet fans. A 75% level of chassis perforation guarantees good ventilation and cooling. As an option, three further fans can be installed for the cooling of the rear I/O area. A fan control can also be integrated.
Monolithic backplane included
For CompactPCI systems with horizontal board assembly, Schroff has developed a new 64-bit range of CompactPCI backplanes with rear I/O that conforms to PICMG 2.0 Rev. 3.0. The backplanes for 6U CompactPCI hot-swappable boards are available for 2, 4, 6 and 8 slot versions. They are configured as continuous monolithic 9U backplanes with an integrated 3U wide area for pluggable 3U/8 HP hot-swappable power supplies.
4 U CompactPCI system for horizontal board assembly
With the 'monolithic solution' the cabling effort between power backplane and CompactPCI backplane and voltage losses on the cables, are avoided. As a standard there are one or two connection facilities (P47 connectors) on the power backplane for the assembly of 19" CompactPCI power supplies, which can be operated parallel or redundantly.
As a rule, the front panels of a 19" plug-in unit or an enclosure have to be configured individually. Standard front panels, that are different in size and finish (eg with or without EMC shielding, for CompactPCI, VME, AdvancedTCA systems or for AdvancedMC boards) are available from the Schroff catalogue.
Apart from the mechanical processing such as drilling, milling, cutting threads and profiling, Schroff offers powder coating and screen printing of the front panels, including the production of transparencies. The integration of mounting and EMC shielding kits, eg, collar screws, handles, PB holders and HF springs is also possible.
Clearing the Static: The importance of ESD audits Actum
Circuit & System Protection
An ESD audit is the first step in establishing an effective static control programme in the workplace, and will help identify vulnerable areas and potentially hazardous static zones that require improvement.
Read more...Flat-pack IT enclosure Rittal
Enclosures, Racks, Cabinets & Panel Products
The introduction of the FR IT flat-pack enclosure by Rittal marked an important milestone for the company, bringing a high-capacity, premium IT enclosure to the local market in a convenient and cost-effective flat-pack format for the first time.
Read more...Click-in module carrier frames Phoenix Contact
Enclosures, Racks, Cabinets & Panel Products
The tool-free Heavycon series click-in module carrier frame from Phoenix Contact simplifies the assembly and installation of heavy-duty connectors significantly.
Read more...Die-cast enclosures in non-rectangular formats Communica
Enclosures, Racks, Cabinets & Panel Products
These models from Hammond Manufacturing, the 1590TRP and 1590STP, provide additional flexibility for product designers who require strong aluminium enclosures, but want alternatives to the traditional rectangular form factor.
Read more...Enclosures engineered for extremes RS South Africa
Enclosures, Racks, Cabinets & Panel Products
When electronic components face the relentless demands of heavy industry or unpredictable outdoor elements, Takachi’s IP67 diecast aluminium enclosures provide a robust line of defence.
Read more...Clearing the Static: ESD containers and packaging Actum
Circuit & System Protection Vacuum forming ESD
Electronic components can be damaged by electrostatic discharges. To protect against such damage, electronic assembly parts are often transported or stored in vacuum formed component ...
Read more...Antistatic vinyl flooring Actum
Manufacturing / Production Technology, Hardware & Services
Vinyl is an affordable, antistatic tile or sheet with a life-span greater than 10 years and installed as a permanent electrostatic discharge floor.
Read more...Electrostatic discharge chairs Actum
Circuit & System Protection
An ESD chair forms an integral part of grounding within the electrostatic discharge protected area to prevent potential damage to products.
Read more...Conductive ESD footwear Actum
Circuit & System Protection
Conductive ESD footwear is used in conjunction with other grounding devices, such as a wrist strap, cord, and ESD surface mats, to provide a continuous path to ground.
Read more...IP66 and IP67 Node & Hub enclosures Vepac Electronics
Enclosures, Racks, Cabinets & Panel Products
The idea behind Node & Hub is simple: enclosures should not be an afterthought. They are the backbone of every smart system protecting, mounting, and connecting the technology that makes the modern world tick.
While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.