Test & Measurement


Digital multimeters offer high performance

5 June 2002 Test & Measurement

The MT1000 Series DMM from MajorTech offer a wealth of new features, ranges, speed, accuracy and resolution. This range meets IEC1010-1 CAT III 1000 V and IEC1010-1 CAT IV 600 V safety ratings to withstand overvoltage transients up to 8 kV per IEC 1010-1. All have UL approval. The battery access door allows a fuse or battery to be replaced without breaking the calibration seal. Overmoulding technology in the case disperses shock over more of the case than a conventional rubber boot design. These meters all come with a standard lifetime warranty from MajorTech.

Both the MT1007 and MT1005 boast 0,05% accuracy and 50000 counts of resolution on a dual-reading display, enhancing troubleshooting by giving the ability to correlate two relevant events. The 50 kHz AC bandwidth opens possibilities to test modern applications not possible with conventional DMMs. They have a bright LED backlight as well as an enhanced LCD with larger digits, wide viewing angle and on screen menu selection. Convenient closed case calibration allows adjustments to be made directly through the RS232C port.

The MT1007 measures volts (DC to 1 µV), ohms, amps, conductance, temperature in °C or °F and capacitance up to 5 mF. Other features include continuity and diode test. The dual reading display also has a bargraph for simultaneous readouts such as true-rms AC+DC and Hz, dB, mVdc and more. Besides relative mode and Min/Max average, the meter has a 1 ms Fast Min/Max for capturing peak transients. In addition the MT1007 can store up to 10 measurements in stand-alone operation. The MT1005 is a 5000 count display and measures volts (DC to 10 µV), and has all the same features of the MT1007 except the AC+DC measurement feature.

The MT1003 and MT1001 have 4000 count backlit displays and are designed to withstand falls from benchtops, ladders or other work areas. These two DMMs are suited for technicians in field service, facilities maintenance and production equipment maintenance/installation. The input ranges and functions are protected to the meters' rated voltage so that it will not blow a fuse or be destroyed if connected to live while measuring ohms.

The MT1003 DMM features true-rms AC readings for correct measurement even when harmonics are present. Other features include volts up to 1000 V a.c. and DC, ohms, capacitance, Hz and duty cycle, temperature and amps. A relative mode, data hold, continuity buzzer and diode test are added features. The MT1001 is an average responding DMM that has the same features as the MT1003 except no temperature measurement.



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Smart oscilloscope for faster debug
30 June 2020, Comtest , Test & Measurement
PicoTechnology announced the PicoScope 6000E Series FlexRes oscilloscopes, featuring 8 channels with 500 MHz bandwidth, 16 digital channels, and resolution of 8, 10 or 12 bits. The products work with ...

Read more...
New range of Tektronix DSOs
30 June 2020, Comtest , Test & Measurement
Comtest has released Tektronix’s new TBS2000B series of digital storage oscilloscopes (DSOs) that was developed to meet the performance, usability and affordability needs of both engineers and educators. ...

Read more...
Contactless ESD testing and access control unit
30 June 2020, Actum Group , Test & Measurement
In the electronics manufacturing industry, an electrostatic discharge (ESD) can cause irreparable damage to electronic components. This micro-lightning bolt can burn holes through insulating layers and ...

Read more...
How are IR cameras calibrated and how does ambient temperature affect readings?
30 June 2020, Instrotech , Test & Measurement
Infrared thermometers are calibrated with the help of reference radiation sources, so-called ‘black bodies’. These radiant sources are able to produce different temperatures with a high stability.  ...

Read more...
Thermal monitor for fever screening
30 June 2020, Actum Group , Test & Measurement
The TCSF256 thermal monitor from Actum Group is a fully automated, plug-and-play fever screening unit. It adopts an infrared radiation measurement technique that can measure body temperature by non-contact ...

Read more...
Uncover EMI issues early with simple pre-compliance tests
30 June 2020, Concilium Technologies , Test & Measurement
An effective pre-compliance testing methodology will reduce test cycle times, which ultimately impacts a company’s bottom line.

Read more...
The promise of 5G wireless communications
30 June 2020, Lambda Test , Test & Measurement
The deployment of 5G services worldwide is driving a massive increase in fibre densification for the required fronthaul and backhaul links interconnecting radio base stations and web-scale core packet networks.

Read more...
Phase noise analyser for precision oscillator characterisation
29 April 2020, Altron Arrow , Test & Measurement
To help research and manufacturing engineers make precise and accurate measurement of frequency signals, including those generated by atomic clocks and other high-performance frequency reference modules ...

Read more...
Ethernet tap for IO Ninja
25 March 2020, RF Design , Test & Measurement
Monitoring network communications of your PC can be accomplished without any specialised hardware – just use the Pcap Sniffer plugin of IO Ninja. The task of tapping into the Ethernet traffic of a non-PC ...

Read more...
Bench-top vector signal generator
29 April 2020, RFiber Solutions , Test & Measurement
The T3267E series bench-top vector signal generator from Transcom Instruments has excellent radio frequency performance and rich signal generating function. It can provide arbitrary wave, continuous ...