Power Electronics / Power Management


Understanding Li-SOCL2 primary battery technology

13 November 2013 Power Electronics / Power Management

As many engineers will know, the battery industry has not yet achieved the perfect battery (or rather, cell) technology.

In almost every choice there is always a compromise to be made when selecting the chemistry which best suits a specific application.

I receive a number of calls on a daily basis by design engineers who are selecting a technology for their product and more often than not a very important factor gets overlooked. In this article I hope to provide some basic fundamentals to keep in mind when considering a Lithium-thionyl chloride (Li-SOCL2) cell or battery for a specific application.

It is my experience that, generally speaking, a higher capacity cell is most commonly sought after. Herein lies a common mistake that is made when briefly studying a potential product’s specification sheet. This mistake occurs when the current delivery ability of the cell is over-looked, often as a result of the excitement involved when finding a potential solution. To gain a better insight into this I would like to explain some basic principles about Lithium-thionyl chloride technology.

Effectively there are two basic methods employed by the manufacturers who produce this technology. Each method offers both advantages and disadvantages.

The two methods employed are referred to as the ‘bobbin cell’ and the ‘spiral wound cell’. The following explanation is primarily focused on the D size cell, but the principles apply to most of the sizes within the Li-SOCL2 range.

The bobbin cell allows for a higher capacity; typically what we see here is a capacity ranging from 17 Ah to 19 Ah at a nominal voltage of 3,6 V. The spiral wound cell has a much lower capacity, generally between 13 Ah and 14,5 Ah depending on the brand in question.

So what is the difference then? Well it all has to do with the current requirements of a particular circuit. The spiral wound cell has a much larger electrode surface area which enables a far greater current to be drawn from the cell. Typically a spiral wound D cell can deliver a continuous current of about 1800 mA and a pulse current of about 4000 mA, depending on the brand of cell used.

A factor that must be kept in mind is the effect on the cell of what is referred to as passivation. On a recent visit to SAFT’s Poitiers production facility in France I was fortunate enough to have an in depth discussion with SAFT’s senior applications engineer, Michel Guegan, regarding this very matter.

In brief, passivation can be described as a love-hate relationship at best. On the one hand it is passivation that allows for the excellent shelf life of Li-SOCl2 cells. It is an essential reaction that must occur in the production process, which effectively takes the cell out of short circuit when the electrolyte is added to the cell in the production process.

Passivation can thus be described as a protective layer that forms on the lithium metal layer contained inside the cell. This layer basically inhibits the electrolyte from making contact with the lithium material contained within the cell. It is important to remember that passivation is reversible (please contact me directly to discuss these methods).

The effects of passivation are evident when one attempts to draw current from the cell. By placing a load on the cell, the passivation layer on the lithium metal is broken down but during this process there is a drop in the cell voltage and, depending on the level of passivation, this drop can result in the cell voltage dropping to below 2,0 V in extreme cases before a gradual recovery.

The end result is that the cell cannot deliver the current or the voltage that a circuit may require and hence this could result in an undesirable situation, and one which could have been avoided altogether. There are a number of remedies that can be applied to deal with this factor, which I would gladly discuss with anyone interested.

We should also understand factors that affect Li-SOCl2 cells as far as self-discharge is concerned, as well as passivation. Generally speaking, excessive temperatures will affect both the rate and depth of passivation as well as the rate of self-discharge.

Self-discharge is often overlooked when a particular brand of cell is considered. We typically see a number of brands that offer 19 Ah rated capacity cells when the better quality brands only offer a 17 Ah equivalent. The difference here is that the better quality cell generally has a much better self-discharge rate in comparison, so one could find that they end up with much less capacity when the cell is put to work in the field due to the rate of self-discharge.

In summary, one should always know your circuit’s current requirements and make sure that you select the appropriate cell that can deliver the required levels of current. Remember that the cell will passivate over time, especially if current is not drawn from the cell on a regular basis.

Environmental factors play a significant role in a cell’s performance, so make sure you understand the environment in which the cell will be expected to perform. Lastly, remember that a greater capacity at a lower price does not necessarily mean better lifetime at a bargain price.

My recommendation is always to consider the ramifications of a battery failure or not meeting the stated lifetime expectancy and the consequences thereof on you or your company.

For more information contact Malcolm Southern, Just Batteries, +27 (0)11 023 8846, [email protected], www.justbatteries.co.za



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Rugged railway-grade DC-DC power modules
iCorp Technologies Power Electronics / Power Management
iCorp Technologies has introduced the AIPUPOWER ZCD100 and ZCD150 Series, a family of rugged DC-DC converters designed to meet the demanding electrical and environmental requirements of railway and transportation systems.

Read more...
Four-quadrant regenerative grid simulator
Conical Technologies Power Electronics / Power Management
The IT7900EP series high-performance regenerative grid simulator from ITECH is a full four-quadrant AC grid simulator capable of both sourcing and sinking power.

Read more...
90 W PSU with 150% boost capability
Brabek Power Electronics / Power Management
RECOM’s cost effective REFIN2U-S90/CL DIN rail AC/DC boasts a 90 W rating with a boost capability of 150% for 4,5 seconds to allow for surge loads.

Read more...
Standalone USB PD controller
Future Electronics Power Electronics / Power Management
The STUSB4531 from STMicroelectronics is a standalone USB Power Delivery sink controller designed to streamline the implementation of USB-C power negotiation in sink devices without requiring a full software stack on a host microcontroller.

Read more...
Power module enhances AI data centre power density
Altron Arrow Power Electronics / Power Management
Microchip’s MCPF1525 power module with PMBus delivers 25 A DC-DC power and is stackable up to 200 A.

Read more...
MIL-Spec DC-DC power converters
Vepac Electronics Power Electronics / Power Management
PowerGood has introduced a range of 15 W to 600 W military DC-DC power converters engineered for mission critical defence applications.

Read more...
Compact power MOSFET for high current switching
Future Electronics Power Electronics / Power Management
onsemi’s NTMFSC2D6N08X is a high-performance 80 V N-channel power MOSFET engineered for demanding switching and power conversion applications.

Read more...
DC link capacitors for demanding applications
RS South Africa Power Electronics / Power Management
TDK Corporation has announced the B3271xP series of DC link film capacitors, offering high thermal robustness for demanding automotive and industrial power electronics.

Read more...
N-channel power MOSFETs
TRX Electronics Power Electronics / Power Management
The TSM2N7002 series from Taiwan Semiconductor are logic-level N-channel power MOSFETs designed with low drain-source on-state resistance, reducing conduction losses and improving efficiency in switching applications.

Read more...
Smart power protection, simplified
TRX Electronics Power Electronics / Power Management
onsemi electronic fuses (eFuses) deliver integrated, intelligent protection by combining overcurrent, overvoltage, over-temperature, reverse polarity, and inrush current safeguards in a single compact IC.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.